Jpn. J. Appl. Phys. 12 (1973) pp. 1152-1159 |Next Article| |Table of Contents|
|Full Text PDF (711K)| |Buy This Article|
(Received July 30, 1971)
An analytical expression is obtained for the transient response of a two-layer slab (consisting of a polymer substrate and a sensor layer), and numerical calculations are performed. Experimental data presented here are obtained by a discharge current heating method, which should correspond to the lower substrate temperature and not to that of the sensor. These responses are characterized approximately by an exponential curve with a single time constant, and it is confirmed that these time constants have nearly the same values even in raising and lowering the temperature of the sensor.
URL:
http://jjap.jsap.jp/link?JJAP/12/1152/
DOI: 10.1143/JJAP.12.1152